Medical Equipment Manufacturer Wholesale Economical Emergency Hospital Clinic ICU Medical Ventilator

Still deciding? Get samples of $ !
Request Sample

Product Description

Basic Information
Model NO.
PA-500
Display
LED
Ventilation Mode
IPPV, SIPPV, IMV, Manual
Max Minute Volume
≥ 18L
Back-up Power
At least 4 Hours
Tidal Volume
50-1200ml (Adjustable)
Oxygen Conc.
<50%
Respiratory Freq.
6-60bpm
Pressure Limit
1-6kpa
I:E Ratio
1:1.5 - 1:3
PEEP
1-10CMH2o
Origin
China
PA-500 Ventilator Machine

Lung Ventilator - Emergency Clinical Resuscitation Device

Key Features & Functional Highlights
Control System: Pneumatically driven electrically controlled ventilator, designed for emergency clinical resuscitation and respiratory therapy.
Advanced Display: High visibility, wide-angle LED alphanumeric data display with tactile analog parameter controls.
Precision Sensors: Equipped with high-precision infrared turbine pressure and flow sensors for accurate monitoring.
Power Safety: Automatically converts to standby mode during AC power outages to ensure continuous support.
Smart Diagnostics: Features automated self-checking during startup and an automatic self-calibrating sensor system.
Alarm System: Visual and audible alarms for tidal volume, airway pressure, power failure, and oxygen failure.
Ventilator Detail View 1
Ventilator Detail View 2
Technical Specifications
Parameter Detail Description
ModelPA-500
Ventilation ModeIPPV, SIPPV, IMV, MANUAL
Tidal VolumeAdjustable range: 50-1200ml
Respiratory Frequency6-60bpm
I:E Ratio1:1.5 - 1:3
PEEP1-10cmH2O
IMV Frequency1-12bpm
Pressure Limit1-6kPa
Max Safe Pressure≤6.0kPa
Inspiratory Trigger-4-10cmH2O
Humidifier9 Level adjustable
SIGH1 sigh breath in every 80 breaths
Gas Requirement0.28~0.6MPa medical grade oxygen
Airway Pressure AlarmUpper: 0.9~5.4kPa, Lower: 0.5kPa
Ventilator Operating Interface
Full Ventilator Setup
Frequently Asked Questions
Q1: What are the primary ventilation modes of the PA-500? The PA-500 supports multiple modes including IPPV (Intermittent Positive Pressure Ventilation), SIPPV, IMV (Intermittent Mandatory Ventilation), and Manual mode.
Q2: How long can the ventilator operate during a power failure? The device is equipped with a back-up power supply that ensures the ventilator can operate for at least 4 hours during AC power outages.
Q3: Is the tidal volume adjustable for different patient needs? Yes, the tidal volume is highly adjustable with a range from 50ml to 1200ml, making it suitable for a wide variety of clinical scenarios.
Q4: What kind of safety alarms does the PA-500 include? It features both audible and visual alarms for tidal volume, airway pressure, power failure, and oxygen supply failure to ensure patient safety.
Q5: Does the ventilator include a humidification system? Yes, the PA-500 comes with an integrated 9-level adjustable humidifier to maintain appropriate moisture levels for the patient's respiratory tract.
Q6: What are the gas supply requirements for this machine? The system requires a medical-grade oxygen supply with a pressure range between 0.28 and 0.6 MPa.